Federal NAICS Codes

NAICS 238310: Drywall and Insulation Contractors

Explore obligations, trends, recent awards, and incumbent contractors for NAICS 238310.

NAICS 238310 federal market metrics

Total obligations
$211.6M
Total awards
4,567 awards
Active obligations
$4.1M
Size standard
$19,000,000 receipts

What this NAICS covers

NAICS 238310 covers installation and repair of interior drywall, plasterboard, suspended ceilings, and building insulation materials, including metal stud framing, gypsum board application, taping, finishing, and thermal or acoustic insulation installation.

Federal opportunities under 238310 typically involve installation or replacement of interior gypsum wallboard and suspended ceilings, acoustic or thermal insulation installs, fire-resistive drywall assemblies, patching and joint finishing, and submittal of fire-rating, acoustic, or insulation R-value compliance documentation.

FY2026 snapshot

Obligations
$4.6M
Awards
125
Average award
$36.6K
Change from FY2025
-27.5%

Recent awards

Search contractors

$129,346

STRATEGIC INDUSTRY INC

Department of Veterans Affairs

PIID
36C26126P1291
PSC
Z2DA - REPAIR OR ALTERATION OF HOSPITALS AND INFIRMARIES

$30,850

ACOUSTICAL SOLUTIONS LLC

Departmental Offices

PIID
140D0426P0363
PSC
5640 - WALLBOARD, BUILDING PAPER, AND THERMAL INSULATION MATERIALS

$297,500

KOALA ROOFING LLC

National Oceanic and Atmospheric Administration

PIID
1305M326P0401
PSC
Z1AZ - MAINTENANCE OF OTHER ADMINISTRATIVE FACILITIES AND SERVICE BUILDINGS

$17,820

MOFFETT CONSTRUCTION LLC

Farm Production and Conservation Business Center

PIID
12FPC126P0040
PSC
Z2JZ - REPAIR OR ALTERATION OF MISCELLANEOUS BUILDINGS

$0

KSNL CONSULTING LLC

US Coast Guard

PIID
70Z08126PELIZ0097
PSC
Z2EB - REPAIR OR ALTERATION OF MAINTENANCE BUILDINGS

FAQ

What work fits NAICS 238310?
  • Install Type X fire-rated gypsum assemblies in corridors and shaft walls to achieve specified hourly fire-ratings, including required joint treatment and penetration sealing.
  • Replace damaged interior gypsum board and finish surfaces to match existing texture, performing taping, sanding, and delivering paint-ready surfaces.
  • Install batt, blown-in, or rigid board insulation in walls and ceilings to specified R-values, provide manufacturer certification and installation reports.
  • Construct and install suspended acoustic ceiling grid systems with acoustical panels, seismic hangers, perimeter trim, and required load-bearing details.
When is NAICS 238310 a weak fit?
  • Exterior cladding or siding installation: work on exterior facade systems, rainscreens, or exterior insulation and finish systems is outside the interior drywall and insulation scope.
  • Insulation manufacturing: producing insulation batts, boards, or foam products in a factory is manufacturing activity distinct from on-site installation.
  • Specialty sprayed fireproofing or intumescent coating application requiring structural fireproofing certification: these specialized coatings are procured and certified under separate scopes from standard drywall installation.
What solicitation language points to NAICS 238310?
  • Scope specifies gypsum type and thickness (for example Type X), joint treatment level (Level 3/4/5), required mock-up, and sanding or finishing acceptance criteria.
  • Contract requires R-value documentation, manufacturer installation instructions, batch numbers for insulation materials, and coordination details for vapor barriers and air-sealing.
  • Payment milestones are tied to completed and inspected drywall areas by square footage with acceptance criteria for smoothness, finishing defects, and approved repairs of penetrations.